Verspreidingswaaieruitsteeksel Tight Buffer Binne-veseloptiese kabel (GJFJV)
Tegniese Parameters:
| Fanout Binnenshuise Veseloptiese Kabel (GJFJV) | Kabeldeursnee | Gewig | |
| 2 kerne | 4.5mm | 22.00kg/km | |
| 4 kerne | 4.5mm | 22.00kg/km | |
| 6 kerne | 4.5mm | 23.00 kg/km | |
| 8 kerne | 5.5mm | 27.00 kg/km | |
| 10 kerne | 5.5mm | 30.00kg/km | |
| 12 kerne | 6.0mm | 35.00 kg/km | |
| Bergingstemperatuur (℃) | -20+60 | ||
| Min. Buigradius (mm) | Langtermyn | 10D | |
| Min. Buigradius (mm) | Korttermyn | 20D | |
| Min toelaatbare treksterkte (N) | Langtermyn | 200 | |
| Min toelaatbare treksterkte (N) | Korttermyn | 600 | |
| Drukbelasting (N/100mm) | Langtermyn | 200 | |
| Drukbelasting (N/100mm) | korttermyn | 1000 | |
Veselkenmerk:
| Veselstyl | Eenheid | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| toestand | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| verswakking | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| Verspreiding | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Bandwydte | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Nul dispersie golflengte | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Nul dispersiehelling | nm | ≤0.092 | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ||
| PMD Maksimum Individuele Vesel | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| PMD-ontwerp skakelwaarde | Ps(nm²*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Vesel-afsnygolflengte λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Kabelafsnydinggolflengte λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9.2±0.4 | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10.4±0.8 | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ||
| NumerieseDiafragma (NA) | ---- | ---- | ---- | 0.200± 0.015 | 0.275±0.015 | 0.200±0.015 | |||
| Stap(gemiddelde van tweerigtingmeting) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Onreëlmatighede oor vesellengte en punt | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Diskontinuïteit | |||||||||
| Verskil terugverstrooiingkoëffisiënt | dB/km | ≤0.05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Verswakkingsuniformiteit | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| Kerndiameter | um | 9 | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | ||
| Bekledingsdiameter | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Bekleding nie-sirkelvormig | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| Deklaagdiameter | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Bedekking/vinkkonsentriese fout | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Nie-sirkulêre bedekking | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| Kern/bekleding konsentrisiteitsfout | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Krul (radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Kabelkonstruksies:
Kabeluitsnyding:
Multimodus OM3 8-kernskabel
Enkelmodus 4-kernskabel
Multimodus 50/125 24-kernskabel
Beskrywings:
•Die Distribution Fanout Tight Buffer Indoor Veseloptiese Kabel gebruik 2~48 kern (of meer) en gebruik 900μm of 600μm stywe buffervesel as optiese subkabel. Normaalweg word PVC of LSZH gebruik, maar ook PE of Nilon.
•Die stywe buffervesel word toegedraai met 'n laag aramiedgaring as sterkte-lid, dan voltooi met 'n laag PVC- of LSZH-materiaal as buitemantel.
•Die verspreidingswaaier-uitbuigingsdun buffer binne-veseloptiese kabel se buitemantelkleur:
Enkelmodus: Geel,
Multimodus OM1 / OM2: Oranje,
Multimodus OM3 / OM4: Aqua,
Multimodus OM4: Violet,
Multimodus OM5: Kalk.
Ander kleur is opsioneel.
Toepassing:
+ Gebruik in pigtails en pleisterkoorde.
+ Gebruik as interkonneksielyne van toerusting, en gebruik in optiese verbindings in optiesekommunikasiekamers, datasentrums en optiese verspreidingsrame.
+ Word gebruik in binnenshuise bekabeling, veral as verspreidingskabel.
Eienskappe:
•Goeie meganiese en omgewingseienskappe.
•Vlamvertragende eienskappe voldoen aan die vereistes van relevante standaarde.
•Die meganiese eienskappe van die domkrag voldoen aan die vereistes van relevante standaarde.
•Sag, buigsaam, maklik om te lê en te splits, en met groot kapasiteit data-oordrag.
•Voldoen aan verskeie vereistes van die mark en kliënte.
Toepassing: gebruik vir binnenshuise kabelwaaier-uit multivesel-pigtail/pleisterkoord
+ Gebruik in pigtails en pleisterkoorde.
+ Gebruik as interkonneksielyne van toerusting, en word gebruik in optiese verbindings in optiese
kommunikasiekamers en optiese verspreidingsrame.
+ Gebruik in binnenshuise bekabeling, veral as verspreidingskabel.
Verpakking: