SM Enkelmodus G652D GYTA 24vesels Direkte Begrawing Buitelug Veseloptiese Kabel
GYTA Kabel Tegniese Data
| Kabeltipe | Veseltelling | Buise | Vulstowwe | Kabeldiameter mm | Kabelgewig kg/km | Treksterkte Lang/Kort Termyn N | Weerstand teen druk Lang/Kort Termyn N/100mm | Buigradius Statiese mm |
| GYTA-2~12 | 8~12 | 1 | 4 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-14~18 | 14~18 | 3 | 2 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-20~24 | 20~24 | 4 | 1 | 9.5 | 110 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-26~36 | 26~36 | 4 | 1 | 9.5 | 120 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-38~48 | 38~48 | 4 | 1 | 10.0 | 140 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-50~60 | 50~60 | 5 | 0 | 10.8 | 150 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-62~72 | 62~72 | 6 | 0 | 11.9 | 170 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-74~84 | 74~84 | 7 | 1 | 12.5 | 180 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-86~96 | 86~96 | 8 | 0 | 13.6 | 210 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-98~108 | 98~108 | 9 | 1 | 14.5 | 230 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-110~120 | 110~120 | 10 | 0 | 14.8 | 240 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTS-122~144 | 122~132 | 11 | 1 | 15.4 | 260 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-146~216 | 146~216 | 12 | 0 | 19.8 | 395 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-218~288 | 218~288 | 12 | 0 | 20.8 | 470 | 1000/3000 | 1000/3000 | 10D/20D |
Veselkenmerk:
| Veselstyl | Eenheid | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Toestand | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Verswakking | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Verspreiding | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Bandwydte | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Nul dispersie golflengte | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Nul dispersiehelling | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| PMD Maksimum Individuele Vesel | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| PMD-ontwerp skakelwaarde | Ps(nm²*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Vesel-afsnygolflengte λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Kabelafsnyding golflengte λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numeriese Diafragma (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Stap (gemiddelde van tweerigting) meting) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Onreëlmatighede oor vesellengte en -punt | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Verskil terugverstrooiing koëffisiënt | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Verswakkingsuniformiteit | dB/km | ≤0.01 | ≤0.01 | |||||
| Kerndiameter | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Bekledingsdiameter | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Bekleding nie-sirkelvormig | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Deklaagdiameter | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Bedekking/vink konsentriese fout | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Nie-sirkulêre bedekking | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Kern/bekleding konsentrisiteitsfout | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Krul (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Veselkleur:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Blou | Oranje | Groen | Bruin | Grys | Wit |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Rooi | Swart | Geel | Violet | Pienk | Aqua |
GYTA Kabel Beskrywing
+ Die vesels, 250μm, is in 'n los buis van 'n hoëmodulusplastiek geplaas.
+ Die buise is gevul met 'n waterbestande vulmiddel.
+ 'n Staaldraad, soms omhul met poliëtileen (PE) vir kabel met 'n hoë veseltelling, word in die middel van die kern as 'n metaalsterkte-element geplaas.
+ Buise (en vulstowwe) word om die versterkingslid in 'n kompakte en sirkelvormige kabelkern gestrand.
+ 'nAluminium poliëtileenlaminaat (APL)word rondom die kabelkern aangebring, wat met die vulmiddel gevul is om dit teen waterindringing te beskerm.
+ Die kabel word voltooi met 'n PE-omhulsel.
Konstruksie:
GYTA Kabel Eienskappe:
+ Goeie meganiese en temperatuurprestasie
+ Hoësterkte los buis wat hidrolisebestand is
+ Spesiale buisvulmiddel verseker 'n kritieke beskerming van vesel
+ Spesiaal ontwerpte kompakte struktuur is goed om te verhoed dat los buise krimp
+ PE-omhulsel beskerm kabel teen ultravioletstraling
+ Die volgende maatreëls word getref om die kabel waterdig te verseker:
+ Staaldraad wat as die sentrale sterkte-element gebruik word
+ Los buisvulmiddel
+ 100% kabelkernvulling
+ 100% getoets voor versending.
+ Kabelrollengte: 1 km, 2 km, 3 km, 5 km
GYTA Kabel Toepassing:
+ Aangepas vir buitelugverspreiding.
+ Geskik vir pyplynlegging, direkte begrawing, ondergrondse metode.
+ Langafstand- en plaaslike area netwerkkommunikasie.
Verpakking: