Enkelmodus Sentrale Losbuis GYXTW Lugkabel vir Buitelug Optiese Vesel
GYXTW Veseloptiese Kabel Meganiese Eienskap:
| GYXTW-kabel | Kabeldeursnee | Gewig |
| Veseltelling: 2 vesels tot 24 vesels | 8.0mm+-0.5mm | 70 kg/km |
| 7.0mm + -0.3mm | 50 kg/km | |
| Temperatuurreeks | -40°C+70°C | |
| Min. Buigradius (mm) | Langtermyn | 10D |
| Min BuigingRadius (mm) | Korttermyn | 20D |
| Min toelaatbare treksterkte (N) | Langtermyn | 1200 |
| Min toelaatbare treksterkte (N) | Korttermyn | 1500 |
| Bedryfstemperatuur | -40°C+70°C | |
| Installasietemperatuur | -20°C+60°C | |
| Bergingstemperatuur | -40°C+70°C | |
Veselkenmerk:
| Veselstyl | Eenheid | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Toestand | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Verswakking | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Verspreiding | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Bandwydte | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Nul dispersie golflengte | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Nul dispersiehelling | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| PMD Maksimum Individuele Vesel | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| PMD-ontwerp skakelwaarde | Ps(nm²*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Vesel-afsnygolflengte λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Kabelafsnyding golflengte λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numeriese Diafragma (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Stap (gemiddelde van tweerigting) meting) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Onreëlmatighede oor vesellengte en -punt | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Verskil terugverstrooiing koëffisiënt | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Verswakkingsuniformiteit | dB/km | ≤0.01 | ≤0.01 | |||||
| Kerndiameter | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Bekledingsdiameter | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Bekleding nie-sirkelvormig | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Deklaagdiameter | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Bedekking/vink konsentriese fout | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Nie-sirkulêre bedekking | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Kern/bekleding konsentrisiteitsfout | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Krul (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Veselkleur:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Blou | Oranje | Groen | Bruin | Grys | Wit |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Rooi | Swart | Geel | Violet | Pienk | Aqua |
Wat is GYXTW-kabel?
•GYXTW-veseloptiese kabel, die vesels 250μm, word in 'n los buis van 'n hoëmodulusplastiek geplaas.
•Die buise word gevul met 'n waterbestande vulmiddel.
•Die buis word in die lengte met 'n laag PSP toegedraai.
•Tussen die PSP en die los buis word waterblokkerende materiaal aangebring om die kabel kompak en waterdig te hou.
•Twee parallelle staaldrade word aan die twee kante van die staalband geplaas.
•Die kabel is voltooi met 'n poliëtileen (PE) omhulsel, swart van kleur, om die vesel teen UV te beskerm.
Konstruksie:
Eienskappe:
•Staaldraad parallelle lid, vulstof beskerm buis vesel staalband gepantser.
•Uitstekende meganiese en omgewingsprestasie.
•Kompakte struktuur, ligte gewig kan gerieflik geïnstalleer en eenvoudig bedryf word.
•Ander vesel is beskikbaar: Enkelmodus (G652D, G657A, G657B) en Multimodus (OM1, Om2, Om3, OM4, OM5)
•Veseltelling: 2fo ~ 12fo
•Diameter-opsie: 6.0 mm, 7.0 mm (af fabriek), 8.0 mm
Toepassing:
+ Aangepas vir buitelugverspreiding.
+ Geskik vir lugpyplynlegging.
+ Langafstand- en plaaslike area netwerkkommunikasie.
Verpakking: